Control Inputs
(All) : (Terminals 5, 6, 8, 9)
TTL-compatible
Logic "0" - 0 to 0.8 V
Logic "1" - 3.5 to 5.0 V
Fault Reset:
(Terminal 4)
Pulled up to +5VDC through a 10k Ohm resistor
Logic "1" (open) - Driver enabled and Fault detection enabled
Logic "0" - Resets a Fault condition (driver is disabled when
this input is low). This input must be held low
for
at least 100ms.
Clock Inputs :
(Terminals 5 and 6)
Pulse required; 15 microseconds minimum. The clock input is pulled
up/down internally to +5VDC / 0VDC through
a 10k Ohm resistor, based upon JP2 selection.
Direction Control:
(Terminal 5)
Pulled up to +5Vdc through a 10k Ohm resistor
Logic "1" (open) - CW
Logic "0" - CCW
Excitation Mode
Select: (Terminal 8)
Pulled up to +5Vdc through a 10k Ohm resistor
Logic "1" (open) - Half-step
Logic "0" - Full-step
Power ON/OFF:
(Terminal 9)
Logic "1" (open) - motor current on
Logic "0" - motor current off
Output Current
Rating: (Terminals
1, 2, 3, 11, 12, and 13)
10 Amps/phase maximum operating
current, 7.0 Amps/phase maximum standstill current, over the operating
voltage and temperature range. Motor phase
ratings of 1.0 Amp minimum are required to meet the
minimum
kick level.
Power Requirement:
Anaheim Automation recommended transformer.
Operating
Temperature : 0 to 60 degrees C
It is recommended that the aluminum driver baseplate be mounted on a
larger aluminum plate, or similar heat-conducting
structure, whenever possible. This will prevent the driver baseplate from
overheating and degrading driver
reliability. Fan cooling is also recommended whenever possible.
FUSING:
A 5 Amp Fast Blow fuse in series with the primary winding of the
transformer is required.