K5 Series
CPU Type
Exp Module
Discrete I/O
Analog I/O
Communication
Helpful Links:
CPU - K506
- Two High-Speed Counters
- Two Pulse Train Outputs
- Integrated Analog Inputs and Outputs
- Integrated Analog Outputs
- Relay or Transistor Outputs
- 14 Sinking or Sourcing Inputs
- 10 Relay or Transistor Outputs
- Multiple Communication Ports
- Free IDE
Item | Input Points |
Input Type |
Output Points |
Output Type |
Rated Voltage |
Analog Input |
Analog Output |
COM Ports |
---|---|---|---|---|---|---|---|---|
KNC-PLC-K506-24AT | 14 | Sinking or Sourcing |
10 | Transistor | 85-265 VAC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K506-24AR | 14 | Sinking or Sourcing |
10 | Relay | 85-265 VAC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K506-24DT | 14 | Sinking or Sourcing |
10 | Transistor | 24 VDC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K506EA-30AT | 14 | Sinking or Sourcing |
10 | Transistor | 85-265 VAC | 4 | 2 | Port0: RS232 Port1 & Port2: RS485 |
CPU - K508
- Two High-Speed Counters
- Two Pulse Train Outputs
- Relay and/or Transistor Outputs
- 24 Sinking or Sourcing Inputs
- 16 Transistor and/or Relay Outputs
- Multiple Communication Ports
- Free IDE
Item | Input Points |
Input Type |
Output Points |
Output Type |
Rated Voltage |
Analog Input |
Analog Output |
COM Ports |
---|---|---|---|---|---|---|---|---|
KNC-PLC-K508-40DT | 24 | Sinking or Sourcing |
16 | Transistor | 24 VDC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K508-40AT | 24 | Sinking or Sourcing |
16 | Transistor | 85-265 VAC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K508-40AR | 24 | Sinking or Sourcing |
16 | Relay | 85-265 VAC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
KNC-PLC-K508-40AX | 24 | Sinking or Sourcing |
16 | Relay and Transistor |
85-265 VAC | N/A | N/A | Port0: RS232 Port1 & Port2: RS485 |
Discrete Inputs - K521
- 8 or 16 Sinking or Sourcing Inputs
- Rated for 3.5mA @ 24VDC
- Inputs are Opto-Isolated
- LED Display to Monitor Running Conditions
- Easy Maintenance and Installation
Item | Input Points |
Input Type |
Rated Input Voltage |
Rated Input Current |
---|---|---|---|---|
KNC-PLC-K521-08DX | 8 | Sinking or Sourcing |
Max 24VDC | 3.5 mA |
KNC-PLC-K521-16DX | 16 | Sinking or Sourcing |
Max 24VDC | 3.5 mA |
Discrete Outputs - K522
- 8 or 16 Sinking or Sourcing Outputs
- Transistor or Relay Outputs
- Transistor Outputs are Rated for 500mA @ 24VDC
- Maximum Relay Output: 2A @ 30VDC or 250VAC
- Transistor Outputs are Opto-Isolated
- LED Display to Monitor Running Conditions
- Easy Maintenance and Installation
Item | Output Points |
Output Type |
Output Voltage |
Output Current |
---|---|---|---|---|
KNC-PLC-K522-08XR | 8 | Relay | Max 30VDC or Max 250VAC |
Max 2A |
KNC-PLC-K522-08DT | 8 | Transistor | Max 24VDC | Max 500mA |
KNC-PLC-K522-16DT | 16 | Transistor | Max 24VDC | Max 500mA |
Discrete Inputs/Outputs - K523
- Up to 8 Sinking or Sourcing Inputs
- Up to 8 Relay or Transitor Outputs
- Inputs are Opto-Isolated
- Transistor Outputs are Opto-Isolated
- LED Display to Monitor Running Conditions
- Easy Maintenance and Installation
Item | Input Points |
Output Points |
Input Type |
Output Type |
Rated Input Voltage |
Rated Input Current |
Output Voltage |
Output Current |
---|---|---|---|---|---|---|---|---|
KNC-PLC-K523-08DR | 4 | 4 | Sinking or Sourcing |
Relay | Max 24VDC | 3.5 mA | Max 30VDC or Max 250VAC |
Max 2A |
KNC-PLC-K523-16DR | 8 | 8 | Sinking or Sourcing |
Relay | Max 24VDC | 3.5 mA | Max 30VDC or Max 250VAC |
Max 2A |
KNC-PLC-K523-08DT | 4 | 4 | Sinking or Sourcing |
Transistor | Max 24VDC | 3.5 mA | Max 24VDC | Max 500mA |
KNC-PLC-K523-16DT | 8 | 8 | Sinking or Sourcing |
Transistor | Max 24VDC | 3.5 mA | Max 24VDC | Max 500mA |
Analog Inputs - K531
- Resistance Temperature Detector Module Offered
- Current and Voltage Input Module Offered
- Provides Wide Input Range
- Up to 6 Analog Input Modules in One PLC-K5 System
- 12-bit Conversion for High-Resolution Measurement
- Very Reliable ±0.3% Error
Item | Analog Input |
Digital Output Resolution |
Input Type |
Output Type |
Accuracy |
---|---|---|---|---|---|
KNC-PLC-K531-04IV | 4 | 12-bit | 0-20mA 4-20mA 1-5VDC 0-10VDC |
N/A | 0.3% |
KNC-PLC-K531-04RD | 4 | 12-bit | Pt100, Cu50, Pt1000, Cu100 |
N/A | ±0.3 |
Analog Outputs - K532
- Current and Voltage Outputs
- Provides Wide Output Range
- Up to 6 Analog Output Modules in One PLC-K5 System
- 12-bit Conversion for High-Resolution Measurement
- Very Reliable ±0.3% Error
Item | Analog Output |
Digital Output Resolution |
Output Type |
Accuracy |
---|---|---|---|---|
KNC-PLC-K532-02IV | 2 | 12-bit | 0-20mA 4-20mA 1-5VDC 0-10VDC |
0.5% |
Analog Inputs/Outputs - K533
- Current and Voltage Inputs
- Current and Voltage Outputs
- Provides Wide Input/Output Range
- Up to 6 Analog Input/Output Modules in One PLC-K5 System
- 12-bit Conversion for High-Resolution Measurement
- Very Reliable ±0.5% Error
Item | Analog Input |
Analog Output |
Digital Output Resolution |
Input Type |
Output Type |
Accuracy |
---|---|---|---|---|---|---|
KNC-PLC-K533-04IV | 2 | 2 | 12-bit | 0-20mA 4-20mA 1-5VDC 0-10VDC |
0-20mA 4-20mA 1-5VDC 0-10VDC |
0.5% |
CAN Communication - K541
- Supports CAN2.0A and CAN2.0B Standard
- Communication Baudrates Ranging from 10K~1Mbps
- Boot-Up Configurable via KincoBuilder
- Supports:
- 72 CANopen Slave Stations
- Network Management (NMT)
- Process Data Objects (PDO)
- Service Data Ojects (SDO)
- Preset Emergency Messages
- Node Protection
- Heartbeat Messages
Item | COM Ports |
Service Capacity | Transmission Speeds | Communication Protocol | CANopen Protocols |
---|---|---|---|---|---|
KNC-PLC-K541 | CAN | 72 | 10K~1Mbps | CAN2.0A and CAN2.0B | NMT, PDO, SDO |